Models 200K, 208K, 300K, 308K & OF7

With some models the Oil Control Valve and burner may be situated on the R.H. side of the cooker.

With boiler models, ensure that the water system is filled before lighting.

Never try and relight a hot burner. Wait until it is cold to the touch. 

1. Turn ON the oil supply at the storage tank and at any other control valves.

2. Remove the loose cover to reveal the Oil Control Valve (OCV) and push down the trip lever 'D' until it clicks then release. Turn the OCV control knob 'C' to its highest setting.

3. Allow about 15 minutes for oil to enter the burner.

4. Open the outer burner door and carefully lift off the inner door.

5. Lift or swing clear, the hinged lighting flap cover 'F' to expose the lighting port.

6. Insert a lighted taper or match through the port, to ignite the wick.

7. Carefully close the lighting flap cover and replace the inner door. Close the outer door.

8. Turn the OCV knob 'C' to the low setting for about 30 minutes, to allow the burner to warm to its normal temperature.

9. The cooker can then be operated normally, using the control knob 'C' to achieve the desired temperatures. When cooking is not required  the knob should be turned to the low setting and the flame will remain alight at a low idling rate.

WARNING. If the burner fails to ignite or operate properly; or there is a strong smell of oil or fumes; or you are unsure if the cooker has been serviced recently,  --- DO NOT USE --- Have the appliance checked by a qualified engineer.