TURNING YOUR RAYBURN ON
Models 365G/L & Gas Nouvelle
Before attempting to light the Rayburn ensure that the plumbing system is
filled.
To Light - Open Flue Models only

1. Open the outer burner door 'N' and lift off the inner door 'M'
2. Turn the external gas cock ON, with the groove in line with the
pipe.
Lighting the cooker burner. (Electricity supply not required)
3. Ensure that cooker burner thermostat 'D' is in the OFF position.
Turn on the pilot control button 'Q' so that the slot is in line with the pipe.
(use a screwdriver or coin)
4. Push and hold in the cooker control button 'B' and light the pilot
burner 'C' with a taper.
5. Continue to hold in button 'B' for a further 15 seconds before releasing.
6. Release 'B' and pilot should stay alight. If not wait 3 minutes
and repeat the above, but keeping 'B' pressed for slightly longer.
7. Replace inner door 'M'. Push in and turn cooker burner thermostat to low
position, when the main burner 'E' should light smoothly. This is the normal
thermostat position when the cooker is not required for use.
Lighting the boiler burner.
8. Make sure that the cooker burner has first been lit as above.
9. Switch off main electricity supply to the Rayburn, but turn any external
controls e.g. room thermostat or time-clock to an ON or high setting.
10.Turn the boiler thermostat 'H' to the OFF position.
11. Lift off the inner burner door 'M' taking care as it might be hot.
12. Push and hold in the boiler gas control valve 'F' and light the pilot
burner 'G' with a taper.
13. Keep 'F' pressed in for a further 15 seconds before releasing.
14. Release 'F' and pilot should stay alight. If not, wait 3 minutes
then repeat the procedure, but keeping 'F' held in for slightly longer.
15. Replace inner door ' M'.
16. Switch ON the external electricity supply and turn on the boiler
thermostat 'H' to the desired setting. The main burner 'J' should then light
smoothly.
WARNING. If the burner fails to ignite or operate
properly; or there is a smell of gas or fumes; or you are unsure if the cooker
has been serviced recently, --- DO NOT USE --- Have the appliance checked
by a qualified engineer.
To Light - Balanced Flue Models Only.


Lighting the cooker burner.
1. Open the outer burner door 'N'
2. Ensure that the external gas cock 'A' and the
pilot cock 'Q' are on (groove in line with pipe). Turn the cooker
thermostat 'D' to the OFF position.
3. Push and hold in the cooker pilot control
button 'B' whilst repeatedly pushing the left-hand spark generator button 'S'
until the pilot flame can be seen through the window 'C'
4. Continue holding the button 'B' for at least
15 seconds before releasing.
5. Release 'B' and pilot should stay alight. If not wait 3 minutes
and repeat the above, but keeping 'B' pressed for slightly longer.
6. Push in and turn cooker burner thermostat to low
position, when the main burner 'E' should light smoothly. This is the normal
thermostat position when the cooker is not required for use.
To light boiler burner.
7. Make sure that the cooker burner has first been lit as above.
8. Switch off main electricity supply to the Rayburn, but turn any external
controls e.g. room thermostat or time-clock to an ON or high setting.
9. Turn the boiler thermostat 'H' to the OFF position.
10. Push and hold in the boiler control valve
button 'F' whilst repeatedly depressing the left-hand spark generator 'S' until
the pilot flame can be seen through the window 'G'
11. Keep 'F' pressed in for a further 15 seconds before releasing.
12. Release 'F' and pilot should stay alight. If not, wait 3 minutes
then repeat the procedure, but keeping 'F' held in for slightly longer.
13. Switch ON the external electricity supply and
any other controls then turn on the boiler
thermostat 'H' to the desired setting. The main burner 'J' should then light
smoothly.
|