Home Page  

 

   

RAYBURN COOKERS 
GENERAL QUESTIONS

Previous Page  
 

 

THIS SECTION

GENERAL QUESTIONS


OTHER SECTIONS

SPECIFICATIONS

INSTALLATION

IDENTIFYING
YOUR RAYBURN

FINDING AN
ENGINEER

 

TURNING YOUR RAYBURN ON

Models 460AL & 480AG

Ensure that water system is filled.

Turn ON the gas cock 'E'.  Switch ON the electricity supply.

Ensure that the CDSD button is reset with button pressed in.

To Light Cooker burner.

1. Turn the cooker thermostat to the OFF position.

2.  Press and hold in the FFD button 'C' whilst repeatedly operating the spark generator 'D' until the flame can be seen through the viewing window.

3. Continue to hold button 'C' down for a further 15 seconds.

4. Release 'C' and the pilot should remain alight. If not, Wait 3 minutes, then repeat the procedure, but holding 'C' down for slightly longer.

5. Turn the cooker thermostat to the desired setting. The main burner will now light and increase to its high rate.

6. When the cooker reaches its set temperature, the burner will extinguish leaving the pilot only.

To Light Boiler Burner

1. Ensure that the boiler overheat thermostat is reset with the button pushed in.

2. Switch OFF the electricity supply.

3. Turn OFF the boiler thermostat.

4. Push and hold in the boiler gas control knob 'A' whilst repeatedly operating the spark generator 'B' until the pilot flame can be seen through the viewing window 'F'

5. Continue to hold 'A' in for a further 15 seconds

6. Release 'A' and the pilot should stay alight. If not, Wait 3 minutes, then repeat the procedure, but holding 'A' down for slightly longer.

7. Turn ON the electricity supply, any external controls and the boiler thermostat to the desired temperature. The main burner should now light.

WARNING. If either burner fails to ignite or operate properly; or there is a smell of gas or fumes; or you are unsure if the cooker has been serviced recently,  --- DO NOT USE --- Have the appliance checked by a qualified engineer.